Fluke MET/CAL Procedure ============================================================================= INSTRUMENT: Yokogawa 2433-11: (1 year) CAL VER /5520 DATE: 15-Sep-97 AUTHOR: Fluke Corporation REVISION: $Revision: 1.1 $ ADJUSTMENT THRESHOLD: 70% NUMBER OF TESTS: 7 NUMBER OF LINES: 89 CONFIGURATION: Fluke 5520A STANDARD: Fluke 5500A/COIL ============================================================================= # # Source: # YOKOGAWA Bulletin 2433-E # # Compatibility: # 5500/CAL 5.0 or MET/CAL 5.0 or later. # # Subprocedures: # None # # Required Files: # NONE # # System Specifications: # TUR calculation is based on specification interval of the accuracy file. # The default 5520A accuracy file contains 90 day specs. # # Fluke makes no warranty, expressed or implied, as to the fitness # or suitability of this procedure in the customer's application. # STEP FSC RANGE NOMINAL TOLERANCE MOD1 MOD2 3 4 CON 1.001 DISP Procedure not formally tested with UUT. 1.001 DISP See procedure README file. 1.002 STD Fluke 5500A/COIL 1.003 ASK- R P F V 1.004 ASK+ K X 1.005 HEAD PRELIMINARY INSTRUCTIONS 1.006 DISP Warm-up time: NONE 1.006 DISP Temperature : 18 - 28 degC 1.006 DISP Humidity: <80% 1.007 DISP [32] WARNING 1.007 DISP HIGH VOLTAGE is used or exposed during the performance 1.007 DISP of this calibration. DEATH ON CONTACT may result if 1.007 DISP personnel fail to observe safety precautions. 1.008 HEAD {AC VOLTAGE} 1.009 DISP Connect 5520A to the UUT as follows: 1.009 DISP [32] 5520A NORMAL HI to UUT P2 1.009 DISP [32] 5520A NORMAL LO to UUT P1 1.010 DISP Set the rotary switch to Vrms. 1.011 HEAD AC VOLTAGE: {200V Range} 1.012 5520 200 200.0V 1% 0.5/ 60H SI 2W 2.001 HEAD AC VOLTAGE: {600V Range} 2.002 5520 600 600.0V 1% 0.5/ 60H SI 2W 3.001 HEAD {AC CURRENT} 3.002 DISP Connect a piece of heavy gauge copper from the 5520A 20A 3.002 DISP to AUX LO terminal and clamp the UUT around the wire. 3.003 DISP Set the rotary switch to Arms. 3.004 HEAD AC CURRENT: {20A Range} 3.005 5520 20 20.00A 1% 0.5/ 60H SI HC 2W 4.001 HEAD AC CURRENT: {200A Range} 4.002 DISP Connect the 5500A/COIL to the 5520A 20A and AUX LO 4.002 DISP terminals and clamp the UUT around the coil. 4.003 5520 200 200.00A 1% 0.5/ 60H SI HC T5 5.001 DISP Remove the clamp and disconnect the wire from the 5520A. 5.002 HEAD {AC POWER} 5.003 DISP Connect the 5500A/COIL to the 5520A AUX HI and LO 5.003 DISP terminals and clamp the UUT around the coil. 5.004 DISP Set the rotary switch to kW. 5.005 HEAD AC POWER: {20kW Range} 5.006 M5520 100V SI 5.007 5520 100A 60H SI S T5 # Need 5520A + 5500A/COIL accuracy here. 5.008 ACC 10.00kW TOL 5.009 MEMI Enter the UUT Power reading (in kilowatts). 5.010 MEME 5.011 MEMC 20 kW 2% 1/ 6.001 HEAD AC POWER: {200kW Range} 6.002 DISP Connect the 5500A/COIL to the 5520A 20A and AUX LO 6.002 DISP terminals and clamp the UUT around the coil. 6.003 M5520 500V SI 6.004 5520 200A 60H SI HC S T5 # Need 5520A + 5500A/COIL accuracy here. 6.005 ACC 100.0kW TOL 6.006 MEMI Enter the UUT Power reading (in kilowatts). 6.007 MEME 6.008 MEMC 200 kW 2% 1/ 7.001 END